Newport Power Meter and Detector Legacy and Compatibility
The following table shows the compatibility between each optical power meter and sensor model. Green dot icons () indicate power meter and optical detector combinations are directly compatible, while gray dot icons () power meter and optical detector combinations are incompatible. Otherwise, an adapter is required as mentioned in the table.
Current Power Meter Models
| Power Meters | Photodiode Detectors | ||||||
|---|---|---|---|---|---|---|---|
| Model Number | Connector Type | 818-xx(-L) (BNC) |
818-xx/CM (Detachable 8-pin DIN) |
818-IS-1 (Permanent 8-pin DIN) |
818-xx(-L-FC)/DB (Detachable DB15) |
918 (Obsolete) (14-pin Limo) |
918D(-IS) (Permanent DB15) |
| 1936-R, 2936-R, 1919-R, 844-PE-USB, 843-R, 843-R-USB |
DB15 | 818-SCAL-OPT (DB15 module) |
843-DIN | 843-DIN | |||
| Power Meters | Thermopile Detectors | Pyroelectric Detectors | |||
|---|---|---|---|---|---|
| Model Number | Connector Type | 818P (Obsolete) (Permanent DB15 connector) |
919P (Permanent DB15 connector) |
818E (Permanent DB15 connector) |
919E (Permanent DB15 connector) |
| 1936-R, 2936-R |
DB15 | ||||
| 1919-R, 844-PE-USB, 843-R, 843-R-USB |
DB15 | ||||
Obsolete Power Meter Models
| Power Meters | Photodiode Detectors | ||||||
|---|---|---|---|---|---|---|---|
| Model Number | Connector Type | 818-xx(-L) (BNC) |
818-xx/CM (Detachable 8-pin DIN) |
818-IS-1 (Permanent 8-pin DIN) |
818-xx(-L-FC)/DB (Detachable DB15) |
918 (Obsolete) (14-pin Limo) |
918D(-IS) (Permanent DB15) |
| 1830-R, 1918-C/R, 1928-C, 1931-C, 1935-C, 1935T-C, 1936-C, 2935-C, 2935T-C, 2936-C, 841-PE-USB
|
DB15 | 818-SCAL-OPT (DB15 module) |
843-DIN | 843-DIN | |||
| 815, 825, 835*, 1815-C, 1825-C |
BNC | Remove Cal Module | Remove Cal Module | 818P-BNC | |||
| 840-C, 1830-C, 1835-C, 2832-C |
8-pin DIN | 818-SCAL-OPT (8-pin DIN module) |
818-SCAL-OPT (8-pin DIN module) |
||||
| 841-PE, 842-PE, 1916-C/R, 1917-R |
DB15 | 818-SCAL-OPT (DB15 module) |
841-DIN | 841-DIN | |||
| 1930-C, 2930-C |
14-pin LIMO | ||||||
| 841-P-USB (Black case), 842-E-USB |
DB15 | ||||||
| 841-P-USB (Silver case) |
DB15 | 818-SCAL-OPT (8-pin DIN module) |
841-DIN | 841-DIN | |||
| 842-PE | DB15 | 818-SCAL-OPT (DB15 module) |
841-DIN | 841-DIN | |||
| Power Meters | Thermopile Detectors | Pyroelectric Detectors | |||
|---|---|---|---|---|---|
| Model Number | Connector Type | 818P (Obsolete) (Permanent DB15 connector) |
919P (Permanent DB15 connector) |
818E (Permanent DB15 connector) |
919E (Permanent DB15 connector) |
| 1928-C, 1918-C/R, 1935-C, 1935T-C, 1936-C, 2935-C, 2935T-C, 2936-C, 841-PE-USB |
DB15 | ||||
| 1815-C | BNC | 818P-BNC | |||
| 1825-C | BNC | 818P-BNC | 818P-BNC | ||
| 840-C, 1830-C, 2832-C |
8-pin DIN | ||||
| 1835-C | 8-pin DIN | 818P-DIN | |||
| 841-P-USB (Black case), 841-P-USB (Silver case), 1916-C/R, 1917-R |
DB15 | ||||
| 1930-C, 2930-C |
14-pin LIMO | ||||
| 1931-C, 2931-C |
DB15 | ||||
| 815, 825, 835* |
BNC | ||||
| 841-PE, 842-E-USB, 842-PE |
DB15 | ||||
Notes: Green dot icons () indicate power meter and optical detector combinations are directly compatible, while gray dot icons () power meter and optical detector combinations are incompatible. Otherwise, an adapter is required as mentioned in the table.
* Customer must have an EEPROM for the detector being used with the 835 power meter. Replacement EEPROM are no longer available.
Detector Connectors Key for Proper Compatibility
When you are in doubt whether a new power meter or a detector you purchase from Newport is compatible with the products you already have, check the connectors on the detectors and the receptors on the meter first. make sure that both are the same type. Due to the different technologies used over the history of Newport product offerings, some models are not compatible or adapters are not available.
The 818 series models with the /DB suffix come with a detachable BNC/DB15 calibration module that provides direct compatibility with Newport's current power meter offering. The models with the /CM suffix come with a detachable BNC/8-pin mini-DIN calibration module that provides compatibility with legacy Newport power meters. The standard BNC connector allows flexible interfacing with oscilloscopes, lock-in amplifiers or current meters.
| Connector Type | Detector Model | |
|---|---|---|
![]() |
Detachable DB15 | 818-UV/DB 818-SL/DB 818-IR/DB 818-IG/DB |
![]() |
Detachable 8-Pin Din | 818-UV/CM, 818-SL/CM, 818-IR/CM, 818-IG/CM |
![]() |
BNC (No Cal Module) | 818-UV, 818-SL, 818-IR, 818-IG |
![]() |
Permanent DB15 | 919P Series 918D 918D-IS |
![]() |
Permanent 8-pin DIN | 818-IS-1 |
Legacy Power Meter Models
Newport has been offering optical power meters and sensors for over thirty years. Many products have come and go. You can find Newport's legacy products information here with a recommended replacement product based on the similarities in specifications. Also you can still find the software drivers for many models in our Software & Drivers page. Always make sure to talk with one of Newport applications engineer, however, to select the best model that fits your application requirements.
| Obsolete Model | Replacement Model | Features & Benefits |
|---|---|---|
![]() 1935-C, 2935-C, 1935T-C, 2935T-C |
![]() 1936-R/2936-R High Performance Optical Power & Energy Meter |
|
![]() 1917-R ![]() 1918-R |
![]() 1919-R High Performance Optical Power Meter |
|
![]() 1916-C, 1916-R |
![]() 843-R Hand-Held Laser Power Meter |
|
![]() 841-P-USB ![]() 842-E-USB ![]() 841-PE-USB |
![]() Virtual Power & Energy Meters |
|